Fix copyright years and deduplicate terminal names

Two issues raised in PR review:

1. Copyright year: new files carried "2006" (the project's founding year).
   Updated to "2006-2026" to reflect the actual authorship period.

2. Duplicate terminal names: EPLAN parts can have multiple connection
   templates sharing the same connectionDesignation (e.g. a drive where
   both wire entries of terminal "1" are labelled "1").  QET requires
   unique terminal names for wiring and terminal-diagram generation.

   Resolution order in EdzElementBuilder::build():
   - Unique designation → used as-is.
   - Duplicated designation with distinct sanitised description →
     "designation_description" (e.g. "1_L_P").
   - Otherwise → numeric suffix: "1", "1_2", "1_3", …

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
Shane Ringrose
2026-06-20 22:39:11 +12:00
parent d56bca66da
commit 207c0c9544
10 changed files with 73 additions and 11 deletions
+1 -1
View File
@@ -1,5 +1,5 @@
/*
Copyright 2006 The QElectroTech Team
Copyright 2006-2026 The QElectroTech Team
This file is part of QElectroTech.
QElectroTech is free software: you can redistribute it and/or modify