mirror of
https://github.com/qelectrotech/qelectrotech-source-mirror.git
synced 2026-10-09 21:54:13 +02:00
Warn with a pop-up, not a box, when a wires-per-terminal rule is turned on
Review of #1272: scorpio810 asked for a warning box for users; the inline
box added in 9a55939bb is replaced by a pop-up, as the element editor
gives for unnamed terminals. When OK in Settings > General or in Project
properties turns a rule on (a limit where there was none, or one wire
per folio report), a warning says the rules are experimental, may change
with settings to redo if wires and conductors become separate objects,
and can all be turned off in Settings > General. OK goes on. Changing a
limit that was already on, or turning rules off, shows nothing.
tst_wiringrules: when the warning is due (WiringRules::turnsRuleOn()).
Checked in the GUI from both pages, and that a plain OK shows nothing.
English for translators: "Warning"; "The wires-per-terminal rules are an
experimental feature. They count wires as QElectroTech represents them
today. They could change, and your settings need redoing, if wires and
conductors become separate objects in a future version. All these rules
can be turned off in Configure QElectroTech > General."
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015FPuYPS4T7QuEwjNu22rXD
This commit is contained in:
@@ -118,7 +118,6 @@ GeneralConfigurationPage::GeneralConfigurationPage(QWidget *parent) :
|
||||
ui->m_wiring_rules_cb->setChecked(WiringRules::masterEnabled());
|
||||
{
|
||||
//The rules every project follows unless it sets its own (#1158)
|
||||
ui->m_wiring_rules_warning_layout->addWidget(WiringRulesWarning::create(this));
|
||||
const WiringRules::Settings rules = WiringRules::applicationSettings();
|
||||
ui->m_wiring_max_wires_sb->setValue(rules.max_wires);
|
||||
ui->m_wiring_one_wire_per_report_cb->setChecked(rules.one_wire_per_report);
|
||||
@@ -353,10 +352,14 @@ void GeneralConfigurationPage::applyConf()
|
||||
settings.setValue("diagrameditor/conductor_properties_panel", ui->m_conductor_properties_panel->isChecked());
|
||||
WiringRules::setMasterEnabled(ui->m_wiring_rules_cb->isChecked());
|
||||
{
|
||||
WiringRules::Settings rules = WiringRules::applicationSettings();
|
||||
const WiringRules::Settings before = WiringRules::applicationSettings();
|
||||
WiringRules::Settings rules = before;
|
||||
rules.max_wires = ui->m_wiring_max_wires_sb->value();
|
||||
rules.one_wire_per_report = ui->m_wiring_one_wire_per_report_cb->isChecked();
|
||||
WiringRules::setApplicationSettings(rules);
|
||||
if (WiringRules::masterEnabled() && WiringRules::turnsRuleOn(before, rules)) {
|
||||
WiringRulesWarning::show(this);
|
||||
}
|
||||
}
|
||||
settings.setValue("diagrameditor/autosave-interval", ui->m_autosave_sb->value());
|
||||
|
||||
|
||||
Reference in New Issue