Terminal: rename potential separation to function separation

The checkbox of a terminal element was an all-or-nothing switch: while
it was unticked every conductor property (function, wire colour,
section, number...) crossed to the other side of the terminal, and
once it was ticked nothing did at all.

Rename it to "Function separation" and let one property still cross:
the voltage / protocol, which describes the electrical node itself
rather than one side of it. Conductor::functionSeparatedConductors()
returns the conductors reachable only by crossing such a terminal --
the potential computed with the separations ignored, minus the one
that respects them -- and
ConductorProperties::applyTensionProtocolChange() gives them that one
property, in the conductor properties dialog, the selection panel
multi-edit, the script API and search/replace.

The stored element information stays "potential_isolating", so
existing symbols and projects keep their setting, and the existing
sub-case of terminals sharing a potential-group identifier is
untouched. The German translation of the new label is deliberately
left out of this commit and belongs with the other .ts updates.
This commit is contained in:
Kellermorph
2026-10-11 14:57:42 +02:00
parent 1f70ddb666
commit 561ddc29bf
15 changed files with 275 additions and 26 deletions
+19
View File
@@ -1187,6 +1187,10 @@ QString QetScriptApi::conductorProperty(int folioIndex, const QString &elementUu
describes a potential and not one drawn segment. Setting it on one
conductor and leaving the rest of the potential disagreeing would
produce a file no GUI action could have produced.
One thing stops at a terminal element with its function separation
enabled: every property but the voltage / protocol, which still
crosses it (@see Conductor::functionSeparatedConductors).
@return true if anything was changed, or if it already held that value
*/
bool QetScriptApi::setConductorProperty(int folioIndex, const QString &elementUuid,
@@ -1225,6 +1229,21 @@ bool QetScriptApi::setConductorProperty(int folioIndex, const QString &elementUu
old_value.setValue(c->properties());
new_value.setValue(properties);
m_project->undoStack()->push(new QPropertyUndoCommand(c, "properties", old_value, new_value));
}
//The other side of a function separated terminal element gets the
//voltage / protocol only: it is the one property that still
//describes the electrical node rather than one side of it.
for (Conductor *c : conductor->functionSeparatedConductors(true))
{
ConductorProperties separated_properties = c->properties();
separated_properties.applyTensionProtocolChange(c->properties(), properties);
if (separated_properties == c->properties())
continue;
QVariant old_value, new_value;
old_value.setValue(c->properties());
new_value.setValue(separated_properties);
m_project->undoStack()->push(new QPropertyUndoCommand(c, "properties", old_value, new_value));
}
m_project->undoStack()->endMacro();
return true;