Add options to leave junctions and contact blocks out of the parts list (#1178)
Since #849 the parts list has a row for every contact block (slave) and terminal-type element. Users who draw the dots and bends where wires branch as terminal-type symbols (114_connections) get one empty row per junction: 109 of 151 rows on one reported cabinet. Two options, both off by default so existing exports are unchanged: - leave out the contact blocks: --no-slaves, "no_slaves" in qet_export, or uncheck the new "Contacts esclaves" element type in the dialog; - leave out the junctions: terminal-type elements with no label, designation, manufacturer or manufacturer reference. --no-junctions, "no_junctions", or "Laisser de côté les jonctions" in the dialog. A terminal block with a label or a part number stays. The element type filter had no box for slaves, so every query it built left them out: the export dialog never listed contact blocks, although the command line has since #849. The dialog now checks the new box by default and gives the same rows as --export-bom. The box is unchecked by default elsewhere, so nomenclature tables keep their rows. docs/smart-device-bom.md still said slaves and terminals were excluded; corrected. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -42,10 +42,18 @@ unit conventions and decimal quantities are not changed implicitly.
|
||||
|
||||
## BOM Policy
|
||||
|
||||
The default BOM query exports one row per Simple or Master element. Slave
|
||||
contacts, terminal-strip elements, reports, thumbnails, and conductor
|
||||
definitions are excluded. A Master device is counted once and PLC I/O entries
|
||||
are not expanded. The existing `exclude_from_bom` property is honored by the
|
||||
The default BOM query exports one row per Simple, Master, Slave or Terminal
|
||||
element: an auxiliary contact block and a terminal block are parts of their
|
||||
own (discussion #847). Reports, thumbnails and conductor definitions are
|
||||
excluded. A Master device is counted once and PLC I/O entries are not
|
||||
expanded.
|
||||
|
||||
Two options leave rows out (#1178). Contact blocks: uncheck **Contacts
|
||||
esclaves** in the dialog, or pass `--no-slaves`. Junctions, the
|
||||
terminal-type symbols drawn where wires branch (`114_connections`), which
|
||||
have no label, designation, manufacturer or manufacturer reference: check
|
||||
**Laisser de côté les jonctions**, or pass `--no-junctions`. A terminal block
|
||||
with a label or a part number is kept. The existing `exclude_from_bom` property is honored by the
|
||||
SQL view, including common true representations (`true`, `1`, `yes`, `on`).
|
||||
|
||||
The default columns are:
|
||||
|
||||