Add options to leave junctions and contact blocks out of the parts list (#1178)

Since #849 the parts list has a row for every contact block (slave) and
terminal-type element. Users who draw the dots and bends where wires
branch as terminal-type symbols (114_connections) get one empty row per
junction: 109 of 151 rows on one reported cabinet.

Two options, both off by default so existing exports are unchanged:
- leave out the contact blocks: --no-slaves, "no_slaves" in qet_export,
  or uncheck the new "Contacts esclaves" element type in the dialog;
- leave out the junctions: terminal-type elements with no label,
  designation, manufacturer or manufacturer reference. --no-junctions,
  "no_junctions", or "Laisser de côté les jonctions" in the dialog.
  A terminal block with a label or a part number stays.

The element type filter had no box for slaves, so every query it built
left them out: the export dialog never listed contact blocks, although
the command line has since #849. The dialog now checks the new box by
default and gives the same rows as --export-bom. The box is unchecked by
default elsewhere, so nomenclature tables keep their rows.

docs/smart-device-bom.md still said slaves and terminals were excluded;
corrected.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
ispyisail
2026-10-05 22:08:44 +13:00
parent 32f7b94594
commit 8434b88eb8
17 changed files with 273 additions and 39 deletions
+6 -1
View File
@@ -48,7 +48,7 @@ namespace CLIExport {
qelectrotech --export-dxf <project.qet> <output_dir> [--show-terminals]
qelectrotech --export-cables <project.qet> <output.csv>
qelectrotech --export-wires <project.qet> <output.csv>
qelectrotech --export-bom <project.qet> <output.csv>
qelectrotech --export-bom <project.qet> <output.csv> [--no-slaves] [--no-junctions]
qelectrotech --export-wiring <project.qet> <output.csv>
qelectrotech --export-nets <project.qet> <output.json>
qelectrotech --export-links <project.qet> <output.csv>
@@ -69,6 +69,11 @@ namespace CLIExport {
cables: wiring list (one row per conductor) as CSV.
wires: list of distinct wire numbers as CSV.
bom: bill of materials (one row per element) as CSV.
--no-slaves: leave the contact blocks (slave elements) out of the
bill of materials.
--no-junctions: leave the junctions out of the bill of materials:
terminal-type elements with no label, designation,
manufacturer or manufacturer reference.
wiring: from-to wiring list (one row per conductor) as CSV, read from
the project database. Same logical list as `cables`, which
reads the document XML instead; the two are meant to agree,