Sort the wiring list by wire number as a number, not as text
Follows @scorpio810's review note on merging #630: ORDER BY diagram_position, wire_number sorts wire numbers as text, so "10" comes before "9". Confirmed against the corpus: perceuse.qet put 111 before 12, and affuteuse_250h.qet put 45 before 5. industrial.qet happened to look correct only because its wire numbers are all the same width. Wire numbers are free text and are not always numeric -- perceuse.qet also carries an unresolved "%sequ_1" -- so the ordering has to cope with both. Numeric values come first, ordered by value; anything else follows, ordered as text. The trailing wire_number keeps ties stable. Fixed in both places the query appears: the CLI exporter and the wiring list dialog. They had the same ORDER BY, so fixing only one would have made the dialog and --export-wiring disagree about the order of the same data. Verified on perceuse, affuteuse_250h, industrial and tremie_vibrante: zero out-of-order numeric pairs afterwards, row counts unchanged, and "%sequ_1" now sorts after the numbers rather than among them. Folio 3 of perceuse.qet reads 0 1 2 3 4 4 5 5 6 6 7 7 12 12 where it previously interleaved 111 before 12. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -52,7 +52,14 @@ WiringListDialog::WiringListDialog(QETProject *project, QWidget *parent) :
|
||||
"SELECT wire_number, from_element_label, from_terminal,"
|
||||
" to_element_label, to_terminal, diagram_position"
|
||||
" FROM wiring_list_view"
|
||||
" ORDER BY diagram_position, wire_number"),
|
||||
//Wire numbers are text, so a plain sort puts "10" before "9".
|
||||
//Numeric ones first, ordered by value; anything non-numeric
|
||||
//after, ordered as text. The trailing wire_number keeps ties
|
||||
//stable.
|
||||
" ORDER BY diagram_position,"
|
||||
" CASE WHEN wire_number GLOB '[0-9]*' THEN 0 ELSE 1 END,"
|
||||
" CAST(wire_number AS INTEGER),"
|
||||
" wire_number"),
|
||||
m_project->dataBase()->database());
|
||||
|
||||