Commit Graph

6 Commits

Author SHA1 Message Date
Kellermorph 955dfb3a73 Merge remote-tracking branch 'upstream/master' into wiring-manager
Conflicts resolved in 24 files. Notable decisions:

- ico/icon-themes.qrc: upstream's icon folder restructure kept; the 36
  cable icon entries re-added under the new qet/qet-dark path scheme
  (XML valid, every referenced file exists).
- Toolbar system: upstream's DiagramToolbarSettings now owns the
  toolbar filling. The cable tool is registered as
  diagrameditor.add_cable (generic group loop) and listed on the
  "diagram" toolbar right after the auto-break conductor action,
  separated by a divider, exactly like before the merge.
- Paste: the cable lines of a copy are handed to
  PasteNumberingImport::push() as extra commands, so paste + cable
  lines + the numbering question stay ONE undo step on both paste
  paths (DiagramView::paste and DiagramEventAddPaste::commit).
- PDF links: upstream's deterministic link sorting kept together with
  the cable cross-reference injector (injectLinkTo -> links list).
- Element renumbering: upstream's ElementAutoNumSchemeCommand::renumber
  replaces the old formula-based body of
  QETProject::renumberElementsBySchemeTitle; the cable numbering rule
  API (cableAutoNum, axis priority, rule name) is kept in full.
- Auto-numbering pages: upstream's scheme management kept, the Câbles
  tab added as index 4 (changeToCableTab), both entry points
  changeToCable() and changeToElement() kept side by side.
- SelectAutonumW: dirty tracking and the contextEdited signal moved
  into upstream's insertPartRow() row API, so single-rule mode, the
  rule-removable button and "confirm without change leaves the project
  alone" keep working.
- xrefpropertieswidget: upstream's offset clamping kept; the cable
  branch (Texte field, Police button, hidden display options) kept;
  the stack-overlapping checkbox is hidden for cables.

Verified after the merge: build green (515/515, no errors), ctest
85/86 (only the pre-existing headless tst_menubarkeyboard failure),
offscreen smoke exit 124.
2026-10-09 14:09:08 +02:00
Kellermorph bf9b34398d Add cable management: drawing, cores, numbering, cross-references and cable list
Cables are drawn line objects (toolbar button next to the auto
break/reconnect button, click-move-click, right click cancels), not
components. The type comes from a CSV catalog following the material
list pattern (designation, cores, core colours, editable through the
entry dialog with "Nouvelle entrée" / "Modifier l'entrée").

Each core is bound to the wire its colour label stands on, and the
cable reference is generated per core and written into the Conductor
entry via Conductor::setCableReference(label, cable uuid, slot). The
conductor entry is where it has to live because the terminal strip
plan (Klemmenplan) consumes it in the next step.

Numbering: "Cables" rule under Programmeinstellungen/Neues
Projekt/Nummerierung auto (mirrored in project properties), literal
"W" fallback without a rule, French gate dialog when no rule exists,
Nummerierung menu with the renumber dialog (preferred axis, per-folio
counter, rule and counter state written back, hand-typed names ask,
whole-project scope).

Also included: label block and under-line texts with per-text font and
alignment plus the material-list cell margins, free-core placement and
right-click removal, claim questions for wires of other cables,
multi-selection drag as one undo step, type change with confirmation,
cross-references for type "Cable" (%f-%l%c, own font, clickable links
in exported PDFs), report propagation of the cable definition,
Listes menu (table of contents, material list, terminal strip manager,
terminal generator plugin, cable list), cable list with freely
selectable columns (installation/localisation of cable, start and end,
Blatt start/end, length, used cores...), CSV export dialog with column
pick and preview in the Projekt menu, script API (addTable kind
"cable_list", exportCableList) and a unit test for the type catalog.
2026-10-08 15:56:00 +02:00
ispyisail 8434b88eb8 Add options to leave junctions and contact blocks out of the parts list (#1178)
Since #849 the parts list has a row for every contact block (slave) and
terminal-type element. Users who draw the dots and bends where wires
branch as terminal-type symbols (114_connections) get one empty row per
junction: 109 of 151 rows on one reported cabinet.

Two options, both off by default so existing exports are unchanged:
- leave out the contact blocks: --no-slaves, "no_slaves" in qet_export,
  or uncheck the new "Contacts esclaves" element type in the dialog;
- leave out the junctions: terminal-type elements with no label,
  designation, manufacturer or manufacturer reference. --no-junctions,
  "no_junctions", or "Laisser de côté les jonctions" in the dialog.
  A terminal block with a label or a part number stays.

The element type filter had no box for slaves, so every query it built
left them out: the export dialog never listed contact blocks, although
the command line has since #849. The dialog now checks the new box by
default and gives the same rows as --export-bom. The box is unchecked by
default elsewhere, so nomenclature tables keep their rows.

docs/smart-device-bom.md still said slaves and terminals were excluded;
corrected.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 22:08:44 +13:00
ispyisail b034d3c5b3 Include slave and terminal elements in the bill of materials
A slave and a terminal are both routinely separately orderable hardware. A
circuit breaker can carry ten or twenty auxiliary blocks, each with its own
order code, and a terminal block is a purchased part in its own right.
Neither was reaching the bill of materials.

Decided in discussion #847: @IBSYSLevi -- "I would not expect that a defined
piece of hardware is excluded from BOM when not specifically defined as so" --
with use cases from @jozi332 covering Siemens breakers with ten to twenty
auxiliary blocks and PLC cards carrying per-channel data.

Two filters had to change, which is easy to miss: BomExport::defaultQuery()
and, upstream of it, the WHERE clause of element_nomenclature_view itself.
Changing only the query does nothing for slaves, because the view had already
removed them. Terminals were already in the view, so they appeared as soon as
the query allowed them -- which made a half-finished change look like it had
worked.

Measured on examples/industrial.qet, which holds 96 terminals and 41 slaves:
258 rows before, 354 with terminals, 395 with both. A slave given a
manufacturer and part number now appears in the export; previously it could
not, at any setting.

Nothing that should stay out of a bill of materials is newly included. The
folio report arrows and the conductor definition are still excluded because
they are not hardware, and anything else -- a relay's own auxiliary contact,
which is not orderable separately -- is kept out with exclude_from_bom, which
the view already honours and which #721 and #765 made settable on the symbol
itself.

tst_smart_device is updated rather than weakened. @enesgursoy6110 wrote it in
#830 to prove the filter works, inserting rows designated "Must not be
exported"; the slave and terminal rows now carry real designations and are
asserted present, and a folio report arrow takes over as the negative case,
so the test still proves filtering happens -- at the boundary we now want.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-13 02:00:50 +12:00
ispyisail f6f68871d1 Include QVariant in bomexport.cpp
exportBomCsv() calls query.value(i).toString(). QSqlQuery::value() returns
a QVariant, but the translation unit only ever sees the forward declaration
that arrives through qobject.h, so the call does not compile:

  sources/bomexport.cpp:79:50: error: invalid use of incomplete type
  'class QVariant'
     79 |    values.append(query.value(i).toString());

Reproduced on a clean checkout of master with Qt 5.15.18. Qt6 pulls the
full definition in by another path, so the Windows CI workflow does not
see it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01N64mk33R9GdbU1PkYcc9SP
2026-09-12 18:48:13 +12:00
enesgursoy6110 77f8e26ffc Address smart device BOM review feedback 2026-09-11 20:12:09 +03:00