Two issues raised in PR review:
1. Copyright year: new files carried "2006" (the project's founding year).
Updated to "2006-2026" to reflect the actual authorship period.
2. Duplicate terminal names: EPLAN parts can have multiple connection
templates sharing the same connectionDesignation (e.g. a drive where
both wire entries of terminal "1" are labelled "1"). QET requires
unique terminal names for wiring and terminal-diagram generation.
Resolution order in EdzElementBuilder::build():
- Unique designation → used as-is.
- Duplicated designation with distinct sanitised description →
"designation_description" (e.g. "1_L_P").
- Otherwise → numeric suffix: "1", "1_2", "1_3", …
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Wires EPLAN .edz import into the elements panel. EdzImporter orchestrates
EdzArchive -> EdzPart -> EdzElementBuilder and writes the generated .elmt into a
destination collection folder (named by order number). A right-click
"Importer une piece EPLAN (.edz)..." action on a writable collection directory
opens a file picker, runs the importer into that folder's fileSystemPath() and
reloads the panel; errors surface via QetMessageBox. Modeled on newElement().
EdzImporter verified headless against the Python oracle for KG6000/MFH200/
R1D200; the panel wiring is built/tested via the WSL Qt5+KF5 build.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>