Several terminals of the catalog have the same width (6.2 mm: Phoenix
Contact UT 4 and ST 4; 5.2 mm: WAGO 2002 and Phoenix Contact ST 2,5...).
Only the width was stored, so on reopening the first entry with that
width was shown instead of the terminal that was chosen.
- New element information terminal_catalog_entry: the label of the
terminal chosen in the catalog (e.g. "Phoenix Contact ST 4").
- Choosing a terminal also fills the manufacturer and manufacturer
reference informations (bill of materials, %{manufacturer_reference}),
only when they are empty or still hold what the previous catalog entry
wrote: a value typed by the user is never overwritten.
- Element editor: the manufacturer and the exact terminal are restored on
reopening. A width typed by hand, or stored before this change, stays a
plain width instead of taking the first terminal with the same width.
- Terminal strip editor: new "Manufacturer" combo filtering the terminals
proposed in the Width column (with the section filter); the column shows
"6,2 - Phoenix Contact ST 4", and copy/paste keeps the terminal.
Existing projects are unchanged: without the new information, only the
width is used, as before.
Terminal block elements can now define, in the element properties
dialog (Terminal block element group):
- the section in mm2 (combo box with the usual sections, editable)
- the width / manufacturer reference (Weidmuller, Phoenix Contact,
WAGO, ABB Entrelec), filtered by the selected section
- the color, using the palette of the terminal strip (editable,
accepts a name, #rrggbb or #rrggbb/#rrggbb)
Values are stored in the element informations (terminal_section,
terminal_width, terminal_color) with the dot as decimal separator,
the keys already read by RealTerminal. An empty value removes the key.
The sections and the manufacturer widths move from
terminalstripmodel.cpp to the new header-only terminalcatalog.h,
shared by the terminal strip editor and the element editor.