The MSI registers both shortcuts with the arguments QET needs to find its
data ("Point directly to qelectrotech.exe with all required arguments"),
but the QElectroTech.Document\shell\open\command registry value was
written without them:
"[INSTALLDIR]bin\qelectrotech.exe" "%1"
Launching from the Start Menu therefore works, while double-clicking a
.qet file does not: Explorer sets the working directory to the document's
folder, and the compiled-in data paths are relative, so nothing is found
there. The most visible symptom is the interface always coming up in
French, because no translation loads and the source strings are French.
Give the file association the same arguments as the shortcuts.
Reported by mr-rfh in #554, who diagnosed it and arrived at exactly this
registry value by hand.
+ AllowSameVersionUpgrades="yes" to <MajorUpgrade>
windows-msi.yml — in the ‘Extract version’ step, calculate a unique GUID
based on the commit’s SHA, then pass -d ‘ProductCode=$productGuid’ to the WIX build
This ensures that each build will have a different ProductCode → MajorUpgrade will always be triggered
- Use SetProperty + WixQuietExec two-step pattern to pass runtime
INSTALLDIR to a deferred CustomAction (fixes WIX1077 and WIX0400)
- Add WixToolset.Util.wixext/7.0.0 extension (required for WixQuietExec)
- Fix condition syntax: collapse multi-line conditions to single line
- Add -ext WixToolset.Util.wixext to wix build command in windows-msi.yml
**`build-aux/windows/QElectroTech.wxs`**
- Desktop and Start Menu shortcuts now point directly to `bin\qelectrotech.exe` with all required arguments (`--common-elements-dir`, `--common-tbt-dir`, `--lang-dir`, `-style windowsvista`) — no `.bat` wrapper needed
- Added a deferred `CustomAction` that runs after `InstallFiles` and recursively sets all files in `elements\` to read-only using an inline PowerShell command
**`.github/workflows/windows-msi.yml`**
- Replaced the step that created `Lancer QET.bat` with a step that removes it from the artifact before the WiX build, so it is not embedded in the MSI
- The `.bat` file remains untouched in the ZIP portable build (managed by `windows-build.yml`)
- No console window flashing when launching QElectroTech from the MSI shortcuts
- The `elements\` directory is properly set to read-only after installation, as required
- Cleaner MSI package — no `.bat` file shipped to end users installing via MSI