Review of #1205:
- The scene gives no order for its selection, so the "first" wire whose
values the panel shows could change between two selections of the
same wires. The wires are now sorted top to bottom, then left to right.
- A text field the selected wires do not agree on (function, section,
cable...) is shown blank with the hint "Plusieurs valeurs". Typing any
value there, including the first wire's own, now differs from what was
shown, so it reaches every wire: 1.5 mm² on a 1.5 and a 2.5 wire works.
- The conductor text is locked while several wires are selected: the same
number on all of them would make duplicates. "Apply to all conductors
of this potential" with one wire selected still sets the number on the
whole potential.
- One edit of N wires emitted N signals, each reloading the panel. They
are now gathered into one reload, which matters since a reload reads
every selected wire to find the mixed fields. Selections and targets
are de-duplicated with sets, and a wire reached through an earlier
wire's potential is not walked again. An edit that changes nothing
returns before any potential is walked.
The rules move to sources/conductormultiedit.h, templates over the wire
type, so tst_conductormultiedit can check them against a fake wire:
order, targets with and without potentials, one undo step and its redo
for three wires, and the mixed fields. tst_conductorapplychanges now
gives the other wire the opposite value in every boolean field, so
copying one by mistake fails the test.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Selecting more than one wire left the Selection properties panel empty,
and so did a box selection over a single wire, because it also picks up
the wire's number label.
Now the panel opens for any number of selected wires. A selected wire
label counts as its wire, once, so a box drawn over wires works. The
fields show the first wire's values, a line above them says how many
wires are selected, and an edit is applied to each wire field by field:
setting the function on ten wires leaves each with its own number,
cable and section. With "apply to all conductors of this potential"
ticked, the potentials of all the selected wires follow the same rule.
Each edit is one undo step.
Fields whose values differ between the selected wires are not marked as
such; that can follow if wanted.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Showing a selected conductor's properties in the selection-properties
dock is now a preference, on the General page under Appearance:
"Afficher les propriétés d'un conducteur sélectionné dans le panneau
Propriétés de la sélection". It is off by default, so selecting a
conductor does what it did before unless the user turns it on.
This replaces the View-menu toggle, which defaulted to on; that entry
is dropped in the merge with master. Same setting key
(diagrameditor/conductor_properties_panel).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Addresses the testing feedback on the conductor selection-properties
prototype:
1. Edits were never applied. The dock drives every editor through
setLiveEdit(true), which each editor overrides to connect its field
changes to apply(); ConductorPropertiesEditorWidget didn't override it,
so the call was a no-op. Implement setLiveEdit() to connect the hosted
ConductorPropertiesWidget's controls (commit-style signals) to apply().
A m_updating guard suppresses the signals emitted while the widget is
loaded programmatically, so a partial mid-load state is never committed.
2. Clicking a conductor's text label showed nothing, because the label is
a ConductorTextItem, not a Conductor. Map it to its parentConductor() in
the editor factory, mirroring the double-click-the-label dialog behaviour.
3. The panel sat at a small size hint with empty space below it. Give the
editor an Expanding vertical size policy (and a minimum height) so it
fills the dock like the other editors.
Refs #500