Commit Graph

9 Commits

Author SHA1 Message Date
ispyisail bec0f1c7b4 Fix #1280: junction dot missing where a wire's corner meets a wire it is not wired to
A conductor draws a junction dot at each of its bends that lies on
another conductor. It only looked at the conductors on its own two
terminals, so a bend lying on a conductor of the same potential that
shares no terminal with it got no dot. Dragging the horizontal parts of
a chain of conductors onto one line, as in the report, does exactly that.

Look at every conductor of the potential on the folio instead
(relatedPotentialConductors(false)). The folio scene uses NoIndex, so a
scene lookup at each bend scans every item and made export of the
366-conductor Polonez example 60% slower; walking the potential costs
nothing measurable there (2.08 s vs 2.11 s) or on a 153-conductor
potential (0.97 s both).

The test for one other conductor moves into bendMakesJunction(). It
also stops a point being appended once per matching segment: master drew
the dot above K2 in the fixture ten times.

Across the 23 examples (133 folios) exported to SVG, 6 dots are added,
all at T-joints that had none, and none removed.

tst_junctiondots exports fixtures/junction_dot_shared_potential.qet and
checks for both dots; it fails on master with the dot above K3 missing.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-04 10:57:27 +13:00
Laurent Trinques 2a72e77b3e Merge branch 'master' into fix/pdf-landscape-paper-size 2026-10-02 15:06:00 +02:00
ispyisail 797d502c0a Put a landscape folio on its standard sheet in --export-pdf
The PDF export sizes each page to its folio, and QPageSize rounds a size
within 3 pt of a standard sheet to the sheet. QPageSize knows the sheets
upright only (bar Ledger), so only portrait folios snapped: an A3 landscape
folio came out as a 1190 x 841 pt page, while an A3 portrait one was
842 x 1191, the sheet. A wide folio is now matched upright and turned.

tst_pdfpagesize exports a fixture with an A3 folio each way and checks both
pages are A3; it fails without the change (1190 x 841).

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 22:53:13 +13:00
ispyisail eb2367e400 Put a potential's one text on the same conductor in every run
With "one text per potential" on, the number is drawn on the
potential's longest conductor. When two conductors tie for longest,
longestConductorInPotential() kept whichever it met first, iterating a
QSet<Conductor *> in pointer order -- which changes from run to run. The
same file, exported twice, could put the number on either conductor:
same numbers, different PDF.

A tie is now broken by where the conductors' ends are on the folio, then
by uuid. Not by uuid first: a file with no conductor uuids gets fresh
ones on every load, and a project generated again by a script gets new
ones each time, while the drawing is the same.

tst_potentialtextcarrier exports a fixture with such a tie eight times;
before the fix it failed in each of three tries.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 22:19:39 +13:00
ispyisail fe8498a26c Fix %{machine_manufacturer_reference_auxiliary1..4} never resolving
AssignVariables::replaceVariable() is a fixed list of replacements. Every
auxiliary family is listed for blocks 1 to 4 except the machine
manufacturer reference, which stopped at the plain
%{machine_manufacturer_reference}. A text using one of the four
auxiliary forms printed the variable itself on the folio and in exports.

Add the four, next to their manufacturer-reference neighbours.

Test: tst_resaveunchanged resaves a project with one terminal whose
texts combine each machine reference variable with its neighbour, and
checks the saved texts carry the values. It fails without the fix (the
variable is saved as typed) and passes with it.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 19:40:31 +13:00
ispyisail c0b8472665 Fix bugtracker #345: crash opening a project with an unlinked contact
A contact (slave) not linked to a coil has no element to take its label
from: DynamicElementTextItem::elementUseForInfo() returns null. Since
8985babfe (#978) the composite-text branch of updateLabel() called
element->actualLabel() without checking, so a text built from %{label}
on such a contact crashed QElectroTech while the project was loading
(QETProject::refresh -> Diagram::refreshContents). The project could not
be opened again.

Check the element as the ElementInfo branch above already does; with no
element, %{label} shows empty, as it did before 8985babfe.

Test: tst_resaveunchanged opens a blank project holding one unlinked
contact with a %{label} text. It fails without the fix (the --resave
crashes) and passes with it.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 18:48:48 +13:00
ispyisail c43f550639 Add a Cable column to the wiring list export
Each wire already carries a cable name (Conductor properties -> Cable),
saved in the project, but no export showed it. The wiring list CSV
(Project menu, and --export-cables) now writes it as a last column, so
the list can be sorted or filtered by cable in a spreadsheet.

It goes last so existing columns keep their positions for anyone reading
the file by column number. When the two halves of a wire drawn through a
folio report are joined into one row, their cable names are merged the
same way as colour and section: written once if equal, both if not.

Asked for in issue #405.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 16:50:56 +13:00
ispyisail 972127aa05 Wiring list export: keep every wire at a folio report, print the folio number
A wire drawn to a folio report waited, keyed by its report, for the wire on
the linked report, in a QMap whose insert() replaces: a second wire on the
same report pushed the first out of the list, and a pair with several wires
on a side was joined by whichever came first. On the shipped examples,
re-saved as the export reads them, 130 of 3,189 wires were missing from the
list (industrial 86, m_000 41, affuteuse_250h 3).

All the report halves are now collected first, and two are joined only
when each report of a linked pair has exactly one wire. With several on a
side the diagram does not say which terminal is wired to which, so each
wire gets its own row ending at the report, as an unmatched half already
did. The result no longer depends on the order the folios are saved in.

The Page column printed each folio's number template ("%id/%total") and
the rows were sorted by it. It now prints the number the folio shows, and
the rows are sorted by the folio's position in the project.

tst_wiringlistexport checks a fixture with one report pair of each kind,
and the page column on every example.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 22:59:49 +13:00
ispyisail 2ed85f6fc7 Address review: qRound-consistent guards, regression test
Addresses scorpio810's review of PR #890 (bugtracker #734):

- The four cas "3"/"4" bridge-skip guards now compare qRound()ed
  coordinates, matching how the bridge coordinate itself is computed --
  an exact != would miss a pair already grid-equal after rounding but
  off by a sub-pixel remainder, and still route a degenerate bridge for
  it. Verified no behavior change on the shipped corpus: per-file
  self-retrace counts are identical before/after (every coordinate
  there already lands exactly on-grid).
- Added tests/qttest/tst_conductorselfretrace.cpp, fixture
  qet_bug_repro_resaved.qet (the report's own canonical reproduction):
  exports it via the built binary's --export-svg and asserts no
  conductor path is self-retracing. Confirmed it actually catches the
  regression, not just passes vacuously -- reverted conductor.cpp to
  master and reran: fails, 1 self-retracing path found.

Not changed in code: the cas "4" descending-branch dead-code note (kept
for symmetry, as already agreed) and the schema_unifilaire_voltaique2.qet
trade-off (flagged for the reviewer's own visual check).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 05:08:14 +12:00