Files
qelectrotech-source-mirror/build-aux/windows/QET64.nsi
Laurent Trinques 941efe6405 Typo
2026-04-25 12:05:29 +02:00

506 lines
19 KiB
NSIS
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
; this file is part of installer for QElectroTech
; Copyright (C)2015 QElectroTech Team <scorpio@qelectrotech.org>
;
; This program is free software; you can redistribute it and/or
; modify it under the terms of the GNU General Public License
; as published by the Free Software Foundation; either
; version 2 of the License, or (at your option) any later version.
;
; This program is distributed in the hope that it will be useful,
; but WITHOUT ANY WARRANTY; without even the implied warranty of
; MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
; GNU General Public License for more details.
;
; You should have received a copy of the GNU General Public License
; along with this program; if not, write to the Free Software
; Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA.
; WebSite : https://qelectrotech.org/
;==============================================================================
; NSIS 3.x compatibility notes:
; - Unicode is native in NSIS 3 (no need for Unicode installer plugin)
; - XPStyle is deprecated/removed; ManifestSupportedOS replaces it
; - SetCompressor must appear before any Section/Function
; - SetRegView 64 moved to top of the hidden section (before WriteRegStr)
; - x64.nsh is still available but ${RunningX64} is now also in x64.nsh
; - MUI2.nsh is unchanged; MUI_LANGDLL_ALLLANGUAGES is still valid
; - FileFunc.nsh / Locate macro: unchanged
; - Var /GLOBAL must be declared at global scope, not inside a Section
;==============================================================================
;--------------------------------
; NSIS 3 requires SetCompressor BEFORE any Section or Function
SetCompressor /FINAL /SOLID lzma
;--------------------------------
; Includes
!include x64.nsh
!include "MUI2.nsh"
!include "FileFunc.nsh"
!insertmacro Locate
!insertmacro GetParameters
!insertmacro GetOptions
;--------------------------------
; NSIS 3: Unicode is the default. The installer binary will be Unicode.
; No extra plugin needed.
!ifndef PROC
!define PROC 64
!endif
;--------------------------------
; General Product Description Definitions
!define SOFT_NAME "QElectroTech"
!define SOFT_VERSION "0.5-dev_x86_64-win64+4094"
!define SOFT_WEB_SITE "https://qelectrotech.org/"
!define SOFT_BUILD "1"
;--------------------------------
; General settings
CRCCheck force
BrandingText "${SOFT_NAME}-${SOFT_VERSION}-${SOFT_BUILD}"
; NSIS 3: XPStyle is removed. Use ManifestSupportedOS to declare modern OS support.
; This replaces "XPStyle on" and enables proper DPI awareness + visual styles.
ManifestSupportedOS all
ManifestDPIAware true
; Name and output file
Name "${SOFT_NAME} ${SOFT_VERSION}"
OutFile "Installer_${SOFT_NAME}-${SOFT_VERSION}-${SOFT_BUILD}.exe"
; Default installation folder
InstallDir "$PROGRAMFILES64\${SOFT_NAME}"
; Get installation folder from registry if available
; NSIS 3: InstallDirRegKey still works, but SetRegView 64 must be set at
; runtime (in .onInit) to read 64-bit registry hive correctly.
InstallDirRegKey HKCU "Software\${SOFT_NAME}" ""
; Request admin privileges (required for HKLM / file associations)
RequestExecutionLevel admin
;--------------------------------
; Declare global variables at script scope (NSIS 3 requirement)
; In NSIS 2 these could be declared inside a Section; that still compiles
; in NSIS 3 but triggers a warning. Declare them here.
Var final_qet_exe
Var final_project_ico
Var final_element_ico
Var final_titleblock_ico
;--------------------------------
; MUI Interface Settings
!define MUI_ABORTWARNING
; NSIS 3 ships updated icons; XPUI icons are still present for compatibility.
; You may switch to the modern ones:
!define MUI_ICON "${NSISDIR}\Contrib\Graphics\Icons\nsis3-install.ico"
!define MUI_UNICON "${NSISDIR}\Contrib\Graphics\Icons\nsis3-uninstall.ico"
!define MUI_WELCOMEFINISHPAGE_BITMAP ".\images\wizard.bmp"
!define MUI_WELCOMEFINISHPAGE_BITMAP_NOSTRETCH
!define MUI_HEADERIMAGE
!define MUI_HEADERIMAGE_BITMAP ".\images\header.bmp"
;--------------------------------
; Language Selection Dialog Settings (remember chosen language in registry)
!define MUI_LANGDLL_REGISTRY_ROOT "HKCU"
!define MUI_LANGDLL_REGISTRY_KEY "Software\${SOFT_NAME}"
!define MUI_LANGDLL_REGISTRY_VALUENAME "Installer Language"
;--------------------------------
; Pages
!define MUI_COMPONENTSPAGE_SMALLDESC
!insertmacro MUI_PAGE_WELCOME
!insertmacro MUI_PAGE_LICENSE "files\LICENSE"
!insertmacro MUI_PAGE_COMPONENTS
!insertmacro MUI_PAGE_DIRECTORY
!insertmacro MUI_PAGE_INSTFILES
!insertmacro MUI_UNPAGE_CONFIRM
!insertmacro MUI_UNPAGE_INSTFILES
; Finish page checkbox to launch QElectroTech
!define MUI_FINISHPAGE_RUN "$INSTDIR\Lancer QET.bat"
!define MUI_FINISHPAGE_RUN_NOTCHECKED
!define MUI_FINISHPAGE_RUN_TEXT "$(Check)"
!insertmacro MUI_PAGE_FINISH
;--------------------------------
; Languages
; NSIS 3: MUI_LANGDLL_ALLLANGUAGES is still supported and works as before.
!define MUI_LANGDLL_ALLLANGUAGES
!insertmacro MUI_LANGUAGE "English" ; first = default
!insertmacro MUI_LANGUAGE "Korean"
!insertmacro MUI_LANGUAGE "French"
!insertmacro MUI_LANGUAGE "Spanish"
!insertmacro MUI_LANGUAGE "Russian"
!insertmacro MUI_LANGUAGE "Portuguese"
!insertmacro MUI_LANGUAGE "Czech"
!insertmacro MUI_LANGUAGE "Polish"
!insertmacro MUI_LANGUAGE "Greek"
!insertmacro MUI_LANGUAGE "Arabic"
!insertmacro MUI_LANGUAGE "German"
!insertmacro MUI_LANGUAGE "Italian"
!insertmacro MUI_LANGUAGE "Romanian"
!insertmacro MUI_LANGUAGE "Catalan"
!insertmacro MUI_LANGUAGE "Croatian"
!insertmacro MUI_LANGUAGE "Dutch"
!insertmacro MUI_LANGUAGE "Danish"
!insertmacro MUI_LANGUAGE "Hungarian"
!insertmacro MUI_LANGUAGE "Japanese"
!insertmacro MUI_LANGUAGE "Mongolian"
!insertmacro MUI_LANGUAGE "Norwegian"
!insertmacro MUI_LANGUAGE "PortugueseBR"
!insertmacro MUI_LANGUAGE "Serbian"
!insertmacro MUI_LANGUAGE "Slovak"
!insertmacro MUI_LANGUAGE "Slovenian"
!insertmacro MUI_LANGUAGE "Swedish"
!insertmacro MUI_LANGUAGE "Turkish"
!insertmacro MUI_LANGUAGE "Ukrainian"
!insertmacro MUI_LANGUAGE "SimpChinese"
!insertmacro MUI_RESERVEFILE_LANGDLL
; Language strings for all supported locales
!include lang_extra.nsh
!include lang_extra_fr.nsh
!include lang_extra_missing.nsh
; NOTE: The string "uninstFailed" must be defined in lang_extra.nsh and
; lang_extra_fr.nsh (and any other lang_extra_*.nsh) like so:
; LangString uninstFailed ${LANG_ENGLISH} "Uninstallation of the previous version failed.$\nPlease uninstall QElectroTech manually before continuing."
; LangString uninstFailed ${LANG_FRENCH} "La désinstallation de la version précédente a échoué.$\nVeuillez désinstaller QElectroTech manuellement avant de continuer."
;==============================================================================
; SECTIONS
;==============================================================================
SetOverwrite on
Section "Main Program"
SectionIn RO ; Read-only always installed
SetOutPath "$INSTDIR\bin\"
File "./files/bin/${SOFT_NAME}.exe"
SetOutPath "$INSTDIR"
File "./files/ChangeLog"
File "./files/CREDIT"
File "./files/ELEMENTS.LICENSE"
File "./files/LICENSE"
File "./files/qet_uninstall_file_associations.reg"
File "./files/README"
File "./files/register_filetypes.bat"
File "Lancer QET.bat"
SetOutPath "$INSTDIR"
File /r "./files/ico"
SectionEnd
;---------------------------
SetOverwrite on
SubSection "$(Elements)" SEC01
SetOverwrite on
Section "$(Electric)"
SetOutPath "$INSTDIR\elements"
File /r "./files/elements/10_electric"
SectionEnd
SetOverwrite on
Section "$(Logic)"
SetOutPath "$INSTDIR\elements"
File /r "./files/elements/20_logic"
SectionEnd
SetOverwrite on
Section "$(Hydraulic)"
SetOutPath "$INSTDIR\elements"
File /r "./files/elements/30_hydraulic"
SectionEnd
SetOverwrite on
Section "$(Pneumatic)"
SetOutPath "$INSTDIR\elements"
File /r "./files/elements/50_pneumatic"
SectionEnd
;---------------------------------
SubSection "$(Energy)"
SetOverwrite on
Section "$(water)"
SetOutPath "$INSTDIR\elements\60_energy"
File /r "./files/elements/60_energy/11_water"
File /r "./files/elements/60_energy/"
SectionEnd
SetOverwrite on
Section "$(Refrigeration)"
SetOutPath "$INSTDIR\elements\60_energy"
File /r "./files/elements/60_energy/21_refrigeration"
File /r "./files/elements/60_energy/"
SectionEnd
SetOverwrite on
Section "$(Solar_thermal)"
SetOutPath "$INSTDIR\elements\60_energy"
File /r "./files/elements/60_energy/31_solar_thermal"
File /r "./files/elements/60_energy/"
SectionEnd
SubSectionEnd
SubSectionEnd
;-------------------------------
SetOverwrite on
Section "$(Lang)" SEC02
SetOutPath "$INSTDIR\lang"
File "./files/lang/*.qm"
SectionEnd
SetOverwrite on
Section "$(Titleblocks)" SEC03
SetOutPath "$INSTDIR"
File /r "./files/titleblocks"
SectionEnd
SetOverwrite on
Section "$(Examples)" SEC04
SetOutPath "$INSTDIR"
File /r "./files/examples"
SectionEnd
SetOverwrite on
Section "$(Fonts)" SEC05
SetOutPath "$INSTDIR"
File /r "./files/fonts"
SectionEnd
;--------------------------------
; Component descriptions
!insertmacro MUI_FUNCTION_DESCRIPTION_BEGIN
!insertmacro MUI_DESCRIPTION_TEXT ${SEC01} $(var1)
!insertmacro MUI_DESCRIPTION_TEXT ${SEC02} $(var2)
!insertmacro MUI_DESCRIPTION_TEXT ${SEC03} $(var3)
!insertmacro MUI_DESCRIPTION_TEXT ${SEC04} $(var4)
!insertmacro MUI_DESCRIPTION_TEXT ${SEC05} $(var5)
!insertmacro MUI_FUNCTION_DESCRIPTION_END
;--------------------------------
; Hidden section: registry, shortcuts, file associations
Section ""
SetOutPath "$INSTDIR"
; NSIS 3 on 64-bit Windows: set 64-bit registry view BEFORE any WriteRegStr
; so keys land in HKLM\SOFTWARE (not the Wow6432Node redirect).
SetRegView 64
; Store installation folder
WriteRegStr HKCU "Software\${SOFT_NAME}" "" $INSTDIR
; Uninstall registry entries
WriteRegStr HKLM "Software\Microsoft\Windows\CurrentVersion\Uninstall\${SOFT_NAME}" \
"DisplayName" "${SOFT_NAME} (remove only)"
WriteRegStr HKLM "Software\Microsoft\Windows\CurrentVersion\Uninstall\${SOFT_NAME}" \
"UninstallString" '"$INSTDIR\Uninstall.exe"'
; Create uninstaller
WriteUninstaller "$INSTDIR\Uninstall.exe"
; Build paths for icons and launch script
StrCpy $final_qet_exe "$INSTDIR\Lancer QET.bat"
StrCpy $final_project_ico "$INSTDIR\ico\application-x-qet-project.ico"
StrCpy $final_element_ico "$INSTDIR\ico\application-x-qet-element.ico"
StrCpy $final_titleblock_ico "$INSTDIR\ico\application-x-qet-titleblock.ico"
; File associations .qet
WriteRegStr HKEY_CLASSES_ROOT "Applications\qelectrotech.exe\shell\open\command" "" \
'"$final_qet_exe" "%1"'
WriteRegStr HKEY_CLASSES_ROOT ".qet" "" "qet_diagram_file"
WriteRegStr HKEY_CLASSES_ROOT "qet_diagram_file" "" "Diagram QET"
WriteRegDWORD HKEY_CLASSES_ROOT "qet_diagram_file" "EditFlags" 0x00000000
WriteRegDWORD HKEY_CLASSES_ROOT "qet_diagram_file" "BrowserFlags" 0x00000008
WriteRegStr HKEY_CLASSES_ROOT "qet_diagram_file\DefaultIcon" "" "$final_project_ico"
WriteRegStr HKEY_CLASSES_ROOT "qet_diagram_file\shell\open\command" "" '"$final_qet_exe" "%1"'
; File associations .elmt
WriteRegStr HKEY_CLASSES_ROOT ".elmt" "" "qet_element_file"
WriteRegStr HKEY_CLASSES_ROOT "qet_element_file" "" "Element QET"
WriteRegDWORD HKEY_CLASSES_ROOT "qet_element_file" "EditFlags" 0x00000000
WriteRegDWORD HKEY_CLASSES_ROOT "qet_element_file" "BrowserFlags" 0x00000008
WriteRegStr HKEY_CLASSES_ROOT "qet_element_file\DefaultIcon" "" "$final_element_ico"
WriteRegStr HKEY_CLASSES_ROOT "qet_element_file\shell\open\command" "" '"$final_qet_exe" "%1"'
; File associations .titleblock
WriteRegStr HKEY_CLASSES_ROOT ".titleblock" "" "qet_titleblock_file"
WriteRegStr HKEY_CLASSES_ROOT "qet_titleblock_file" "" "Titleblock QET"
WriteRegDWORD HKEY_CLASSES_ROOT "qet_titleblock_file" "EditFlags" 0x00000000
WriteRegDWORD HKEY_CLASSES_ROOT "qet_titleblock_file" "BrowserFlags" 0x00000008
WriteRegStr HKEY_CLASSES_ROOT "qet_titleblock_file\DefaultIcon" "" "$final_titleblock_ico"
WriteRegStr HKEY_CLASSES_ROOT "qet_titleblock_file\shell\open\command" "" '"$final_qet_exe" "%1"'
SetShellVarContext all ; apply shortcuts for all users
; Start Menu shortcuts
CreateDirectory "$SMPROGRAMS\${SOFT_NAME}"
CreateDirectory "$SMPROGRAMS\${SOFT_NAME}\Manual"
CreateDirectory "$SMPROGRAMS\${SOFT_NAME}\Upgrade"
CreateShortCut "$SMPROGRAMS\${SOFT_NAME}\QElectroTech.lnk" \
"$INSTDIR\Lancer QET.bat" 0 "$INSTDIR\ico\qelectrotech.ico"
CreateShortCut "$SMPROGRAMS\${SOFT_NAME}\Uninstall QElectroTech.lnk" \
"$INSTDIR\Uninstall.exe"
; Desktop shortcut
CreateShortCut "$DESKTOP\QElectroTech.lnk" \
"$INSTDIR\Lancer QET.bat" 0 "$INSTDIR\ico\qelectrotech.ico"
; Internet shortcuts
WriteINIStr "$SMPROGRAMS\${SOFT_NAME}\Manual\Manual_English.url" \
"InternetShortcut" "URL" "https://download.qelectrotech.org/qet/manual_0.7/build/index.html"
WriteINIStr "$SMPROGRAMS\${SOFT_NAME}\Manual\Manual_Russian.url" \
"InternetShortcut" "URL" "https://download.qelectrotech.org/qet/joshua/html/QET_ru.html"
WriteINIStr "$SMPROGRAMS\${SOFT_NAME}\Upgrade\Download.url" \
"InternetShortcut" "URL" "https://download.qelectrotech.org/qet/builds/nightly/"
WriteINIStr "$SMPROGRAMS\${SOFT_NAME}\Donate.url" \
"InternetShortcut" "URL" "https://www.paypal.com/cgi-bin/webscr?cmd=_s-xclick&hosted_button_id=ZZHC9D7C3MDPC"
; Mark installed elements as read-only
${Locate} "$INSTDIR\elements\" "/L=FD /M=*.elmt" "LocateCallback"
IfErrors 0 +2
; MessageBox MB_OK "Error in Locate" ; uncomment for debugging
SectionEnd
;--------------------------------
; Locate callback sets FILE_ATTRIBUTE_READONLY on each .elmt file
Function LocateCallback
SetFileAttributes $R9 FILE_ATTRIBUTE_READONLY
Push $0
FunctionEnd
;==============================================================================
; INSTALLER FUNCTIONS
;==============================================================================
Function .onInit
; NSIS 3: SetRegView in .onInit ensures InstallDirRegKey reads the right hive
SetRegView 64
!insertmacro MUI_LANGDLL_DISPLAY
; Abort if not running on a 64-bit OS
${IfNot} ${RunningX64}
MessageBox MB_OK|MB_ICONSTOP $(wrongArch)
Abort
${EndIf}
; ----------------------------------------------------------------
; Auto-uninstall previous version before installing new one
; ----------------------------------------------------------------
ReadRegStr $R0 HKLM \
"Software\Microsoft\Windows\CurrentVersion\Uninstall\${SOFT_NAME}" \
"UninstallString"
; No previous installation found → proceed normally
StrCmp $R0 "" done
; Also read the install dir of the previous version
ReadRegStr $R1 HKCU "Software\${SOFT_NAME}" ""
; Ask user whether to uninstall the existing version
MessageBox MB_OKCANCEL|MB_ICONEXCLAMATION "$(installed)" IDOK uninst
Abort ; user clicked Cancel → stop the installer
uninst:
; Remove surrounding quotes from the UninstallString if present
; (some installers write: "C:\path\Uninstall.exe" — ExecWait needs clean path)
StrCpy $R2 $R0 1 ; first character
StrCmp $R2 '"' 0 unquoted
; Strip leading and trailing quote
StrCpy $R0 $R0 "" 1 ; remove leading "
StrLen $R3 $R0
IntOp $R3 $R3 - 1
StrCpy $R0 $R0 $R3 ; remove trailing "
unquoted:
; Run the uninstaller silently, keeping it in its own directory
; _?= prevents NSIS from copying the uninstaller to a temp folder,
; so it can delete itself and the whole $INSTDIR tree.
ClearErrors
${If} $R1 != ""
ExecWait '"$R0" /S _?=$R1' ; silent uninstall using saved install dir
${Else}
ExecWait '"$R0" /S' ; fallback if install dir unknown
${EndIf}
IfErrors uninstall_failed
; Verify the old installation is gone before continuing
${If} $R1 != ""
IfFileExists "$R1\${SOFT_NAME}.exe" uninstall_failed
IfFileExists "$R1\bin\${SOFT_NAME}.exe" uninstall_failed
${EndIf}
Goto done
uninstall_failed:
MessageBox MB_OK|MB_ICONSTOP "$(uninstFailed)"
Abort
done:
FunctionEnd
;==============================================================================
; UNINSTALLER SECTION
;==============================================================================
Section "Uninstall"
SetRegView 64 ; NSIS 3: required so we delete from the correct hive
SetShellVarContext all
; Remove Start Menu shortcuts
RMDir /r "$SMPROGRAMS\${SOFT_NAME}"
; Remove Desktop shortcut
Delete "$DESKTOP\QElectroTech.lnk"
; Remove application files
Delete "$INSTDIR\*.*"
RMDir /r "$INSTDIR"
; Remove installation registry keys
DeleteRegKey HKLM "Software\Microsoft\Windows\CurrentVersion\Uninstall\${SOFT_NAME}"
DeleteRegKey /ifempty HKCU "Software\${SOFT_NAME}"
; Remove file associations registry keys
DeleteRegKey HKEY_CLASSES_ROOT "Applications\qelectrotech.exe"
DeleteRegKey HKEY_CLASSES_ROOT ".qet"
DeleteRegKey HKEY_CLASSES_ROOT "qet_diagram_file"
DeleteRegKey HKEY_CLASSES_ROOT ".elmt"
DeleteRegKey HKEY_CLASSES_ROOT "qet_element_file"
DeleteRegKey HKEY_CLASSES_ROOT ".titleblock"
DeleteRegKey HKEY_CLASSES_ROOT "qet_titleblock_file"
IfFileExists "$INSTDIR" 0 NoErrorMsg
; MessageBox MB_OK "Note: $INSTDIR could not be removed!"
NoErrorMsg:
SectionEnd
;==============================================================================
; UNINSTALLER FUNCTIONS
;==============================================================================
Function un.onInit
SetRegView 64 ; NSIS 3: match the view used during install
!insertmacro MUI_UNGETLANGUAGE
FunctionEnd