mirror of
https://github.com/qelectrotech/qelectrotech-source-mirror.git
synced 2026-10-17 19:34:13 +02:00
5e28ec4246
Linux build and tests / Build and test (Qt 6, Debug) (push) Failing after 1m42s
The section combo boxes of the terminal strip editor and of the element editor now show the nearest AWG / kcmil size next to the section in mm2, for example "2.5 mm² (AWG 14)". The correspondence is approximate (the two systems don't have the same steps) and is stored in TerminalCatalog::awgForSection(). The stored value is unchanged (terminal_section, in mm2).
118 lines
3.9 KiB
C++
118 lines
3.9 KiB
C++
/*
|
|
Copyright 2006-2026 The QElectroTech Team
|
|
This file is part of QElectroTech.
|
|
|
|
QElectroTech is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 2 of the License, or
|
|
(at your option) any later version.
|
|
|
|
QElectroTech is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with QElectroTech. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
#ifndef TERMINALCATALOG_H
|
|
#define TERMINALCATALOG_H
|
|
|
|
#include <QLocale>
|
|
#include <QString>
|
|
#include <QVector>
|
|
|
|
/**
|
|
* @brief The TerminalCatalog namespace
|
|
* Data shared between the terminal strip editor and the element editor :
|
|
* usual sections (mm2) and widths (mm) of the terminals sold by the manufacturers.
|
|
* Only the values found in the catalogs of the manufacturers are listed,
|
|
* any other value can be typed by the user.
|
|
*/
|
|
namespace TerminalCatalog
|
|
{
|
|
/**
|
|
* Width (mm) of a terminal sold by a manufacturer.
|
|
* For ABB Entrelec the value is the spacing (pitch) given by the catalog.
|
|
*/
|
|
struct WidthEntry { double mm; const char *label; double section; };
|
|
|
|
inline const QVector<double> §ions()
|
|
{
|
|
static const QVector<double> sections_ {0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300};
|
|
return sections_;
|
|
}
|
|
|
|
/**
|
|
* @brief awgForSection
|
|
* @param mm2 : a section in mm2
|
|
* @return the nearest AWG / kcmil size, as text ("14", "1/0", "250 kcmil"),
|
|
* or an empty string if the section has no usual equivalent.
|
|
* The correspondence is approximate (the usual table of the manufacturers),
|
|
* the two systems don't have the same steps.
|
|
*/
|
|
inline QString awgForSection(double mm2)
|
|
{
|
|
struct Awg { double mm2; const char *awg; };
|
|
static const Awg table_[] {
|
|
{0.5, "20"}, {0.75, "18"}, {1, "17"},
|
|
{1.5, "16"}, {2.5, "14"}, {4, "12"},
|
|
{6, "10"}, {10, "8"}, {16, "6"},
|
|
{25, "4"}, {35, "2"}, {50, "1/0"},
|
|
{70, "2/0"}, {95, "3/0"}, {120, "250 kcmil"},
|
|
{150, "300 kcmil"}, {185, "350 kcmil"}, {240, "500 kcmil"},
|
|
{300, "600 kcmil"}
|
|
};
|
|
for (const auto &entry : table_) {
|
|
if (qAbs(entry.mm2 - mm2) < 0.0001) {
|
|
return QString::fromLatin1(entry.awg);
|
|
}
|
|
}
|
|
return QString();
|
|
}
|
|
|
|
/**
|
|
* @brief sectionText
|
|
* @param mm2 : a section in mm2
|
|
* @param unit_text : the text of the section with its unit, for example "2,5 mm²"
|
|
* @return @a unit_text followed by the AWG size if there is one : "2,5 mm² (AWG 14)"
|
|
*/
|
|
inline QString sectionText(double mm2, const QString &unit_text)
|
|
{
|
|
const auto awg_ = awgForSection(mm2);
|
|
if (awg_.isEmpty()) {
|
|
return unit_text;
|
|
}
|
|
return awg_.contains(QLatin1String("kcmil"))
|
|
? unit_text + QStringLiteral(" (%1)").arg(awg_)
|
|
: unit_text + QStringLiteral(" (AWG %1)").arg(awg_);
|
|
}
|
|
|
|
inline const QVector<WidthEntry> &widthEntries()
|
|
{
|
|
static const QVector<WidthEntry> entries_ {
|
|
{5.1, "Weidmüller WDU 2.5", 2.5},
|
|
{5.2, "WAGO 2002 (TOPJOB S)", 2.5},
|
|
{6.0, "ABB Entrelec M 4/6", 4.0},
|
|
{6.1, "Weidmüller WDU 4", 4.0},
|
|
{6.2, "Phoenix Contact UT 4", 4.0},
|
|
{8.0, "ABB Entrelec M 6/8", 6.0},
|
|
{8.0, "ABB Entrelec M 4/8", 4.0},
|
|
{8.2, "Phoenix Contact UT 6", 6.0},
|
|
{10.0, "ABB Entrelec M 10/10", 10.0},
|
|
{10.2, "Phoenix Contact UT 10", 10.0},
|
|
{11.9, "Weidmüller WDU 16/ZA", 16.0},
|
|
{12.2, "Phoenix Contact UT 16", 16.0},
|
|
{16.0, "Phoenix Contact UT 35", 35.0},
|
|
{16.0, "Weidmüller WDU 35N", 35.0},
|
|
{26.0, "ABB Entrelec M 35/26.FF", 35.0},
|
|
{31.0, "ABB Entrelec M 70/31.AF", 70.0},
|
|
{35.0, "ABB Entrelec M 120/35.F", 120.0},
|
|
{42.0, "ABB Entrelec M 300/42.FF", 300.0}
|
|
};
|
|
return entries_;
|
|
}
|
|
}
|
|
|
|