The previous grouping compared `connectionDesignation` values (e.g. "1", "2", "3") to detect group boundaries. Those values are pin position numbers within a terminal block, not functional group identifiers, so devices like the ABB ACS880 produced 11+ tiny single-pin "groups" instead of the ~8 functional blocks (AC-IN, Motor-OUT, DC-Bus, Brake-Resistor, Analog-I/O, Digital-I/O, ...) the reviewer identified. Fix: - Add `group` field to EdzPin, populated from the `functiondefinition` attribute on <functiontemplate> (newer EPLAN) or its parent <function> element (older EPLAN). - Sort pins by group first (preserving XML appearance order per group), then by designation within each group using natural sort. - Use `groupKey()` — group when present, designation as fallback — for the group-break detection that drives separator lines and Y-gaps. Parts without any functiondefinition data retain the previous designation-based behaviour unchanged. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>