Files
qelectrotech-source-mirror/sources/import/edz
Shane Ringrose 8268df8a80 edz: name terminals terminalNr.designation (e.g. "XDI.2")
Previous logic resolved duplicate connectionDesignation values by
appending sanitised description text or numeric suffixes, which was
fragile and produced names an electrician could not easily map back to
the physical wiring.

New scheme:
  • terminalNr present  → "XDI.2", "XRO1.3", "XPOW.1" …
  • terminalNr absent   → designation as-is ("L1/U1", "UDC+", "PE") —
    these are busbar / power connections and are already globally unique
  • collision (malformed data) → numeric suffix as safety net

The description (connectiondescription) remains as the human-readable
label beside the terminal symbol, exactly as suggested by plc-user.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-21 08:58:30 +12:00
..

EPLAN .edz part import

Imports a part from the EPLAN Data Portal (.edz) into a QElectroTech element collection. The EPLAN Data Portal is the de-facto parts catalogue for electrical CAD (ifm, Phoenix Contact, Siemens, Rittal, Weidmüller, Schneider…), and components ship as .edz; this lets a QET user drop one straight into a project.

Using it

Right-click a writable collection folder in the elements panel → Import an EPLAN part (.edz)… → choose the file. The generated element is written into that folder and the panel reloads.

What is imported

A .edz is a 7-Zip archive containing a part definition (*.part.xml), an EPLAN macro (*.ema), a product image and metadata. Only the portable part data is used:

  • Terminals — each <functiontemplate> with a physical connection designation becomes a QET terminal, labelled from its connection description.
  • Element information — manufacturer, order number, designation and comment fill the QET element-information fields used by the BOM / nomenclature.
  • Localized names — one <name lang="xx"> per language the part provides, so the element labels itself in any QET UI language.
  • Symbol — a generic symbol is generated (a body rectangle with one west-facing terminal per pin). The EPLAN .ema macro geometry is not reproduced: it is tokenised EPLAN PXF that references EPLAN's own symbol libraries. A generic symbol is sufficient for wiring and BOM; swap in a nicer symbol in the element editor afterwards if desired.

Structure

File Role
edzarchive.* Extract the .edz to a temp dir; locate part.xml
edzsevenzip.* 7-Zip extraction via the bundled LZMA SDK (no external 7-Zip)
edzpart.* Parse part.xml into a portable model
edzelementbuilder.* Build the .elmt element from the model
edzimporter.* Orchestrate the above and write into a collection folder
lzma/ Vendored public-domain LZMA SDK (decode-only subset)

The non-UI classes are deliberately decoupled from the widget so they can be tested headless.

Bundled LZMA SDK

lzma/ contains the decode-only subset of Igor Pavlov's LZMA SDK (public domain — see lzma/LZMA-SDK-LICENSE.txt), so a .edz can be unpacked without an external 7-Zip install. Only 7-Zip-format .edz files are supported; zip-format packages are detected and reported but not yet handled.