Closes the gap left open by the previous commit, at the root rather than
around it.
populateElementTable()/populateElementInfoTable() only inserted elements
matching Simple|Terminal|Master|Thumbnail. That quietly made the element
table mean "the elements a nomenclature cares about" rather than "the
elements of the project": slave elements (relay contacts) and report
elements -- ordinary conductor endpoints -- had no row at all after a
project load, so the wiring list could not name either end of a wire
that terminated on one.
Both tables are now populated with every ElementData::Type, and the type
restriction moves into element_nomenclature_view, which is where a
"what belongs in a bill of materials" decision belongs. The mask in the
view is character-for-character the one the population used to apply, so
a relay contact is still not a BOM line item.
This is safe to do in one place because every consumer of the project
database goes through a view: element_nomenclature_view (the on-diagram
nomenclature table via ElementQueryWidget, the BOM dialog, and the
--export-bom CLI) or project_summary_view (which does not reference
element at all). Nothing queries the element or element_info tables
directly -- checked across the whole tree.
Regression evidence. --export-bom runs updateDB() and then queries
element_nomenclature_view, so it is an exact harness for what the GUI
BOM shows. Captured for 19 projects (all 17 usable examples/ plus two
slave-element fixtures) before and after:
- BOM content byte-identical on all 19, compared as a multiset.
- 18 of 19 are also identical line-for-line in order.
- photovoltaique differs only in the position of three byte-identical
rows among themselves. Its query is ORDER BY label and those rows
share an empty label, so their relative order was never defined;
they are indistinguishable in the output. The on-diagram
nomenclature orders by every displayed column, so a tie there means
the rows are identical on screen too.
Effect on the wiring list, same project and same reload path: element_info
rows 0 -> 2, and the two component columns go from blank to K2 -> K1.
Cost: the database phase of loading examples/industrial.qet (150 folios,
1794 terminals) moves from 0.210 s to 0.233 s.