ispyisail b972dbec4b Number terminals and export wire numbers without building every folio (stage D5)
Terminal numbering builds only the folios holding a terminal. The wire
numbers export reads the wires of the folios not built from the project
database, and walks a built folio's own wires instead of a
DiagramContent, which followed their potentials through folio reports
and built the folios at the other end. The wiring list export names a
folio from its title block, which a folio not built has; it still
builds every folio, writing the whole project out (toXml()).

tst_lazyfolios: wire numbers exported as when built, from a .qet and a
.qetz, building no folio (fails with DiagramContent: 27 built);
terminal numbering builds 7 folios, those with a terminal (fails with
diagrams(): 47); the wiring list as when built. ctest 96/96 eager and
lazy; 342 corpus projects save the same in all four arms.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>