ispyisail 173346c712 qet-mcp: qet_check finds crowded terminals and folio reports with several wires
Discussion #1158 asks for a limit on the wires per terminal. Before any
limit, two read-only checks let anyone count their own projects:

- crowded_terminals: terminals with more than four wires (two double
  ferrules, one either side of the screw), folio reports left out;
- reports_with_several_wires: folio report arrows with more than one
  wire, the rule plc-user proposes for reports.

Both are info, not errors: cable, busbar and single-line symbols carry
more wires on purpose, and a third of the shipped examples' reports have
several. Over the 24 examples: 23 crowded terminals in 10 projects
(the worst, 19, is a cable symbol in affuteuse_250h.qet) and 130 reports
in 4 projects. Plain SQL over the conductor table, so they work on any
current QElectroTech.

test_qet_mcp: the checks are read-only, the exact-answer test lists them,
and a coil wired to five others is reported once with its count (checked
to fail with the threshold raised). 398 tests pass.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015FPuYPS4T7QuEwjNu22rXD