AssignVariables: open QSettings only for element formulas

Every formula evaluation constructed a QSettings, although only element
formulas read it (border-columns_0, for %c). Constructing QSettings is
costly, on Windows a registry lookup, and conductor labels are evaluated
in bulk: Conductor::refreshText() runs for every wire of a folio when it
is built, and for every wire of every built folio when the project or a
title block changes.

Debug build, 40 folios with 4,280 numbered wires:
- refreshText() of every wire: 1,136-1,264 ms before, 203-208 ms after
- opening the project (database fill): 2.24-2.48 s before, 1.46-1.59 s after
- building 39 lazy folios: 15.0-15.3 s before, 12.3-12.5 s after

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Ramon
2026-10-19 13:44:08 +02:00
parent 4fee464919
commit f6c9aeb177
+1 -1
View File
@@ -415,9 +415,9 @@ namespace autonum
m_assigned_label.replace("%M", m_context.plant);
m_assigned_label.replace("%LM", m_context.locmach);
QSettings settings;
if (m_context.has_element)
{
QSettings settings;
if (settings.value("border-columns_0", true).toBool()){
m_assigned_label.replace("%c", QString::number(m_context.element_position.number() - 1));
}else{