ispyisail 8434b88eb8 Add options to leave junctions and contact blocks out of the parts list (#1178)
Since #849 the parts list has a row for every contact block (slave) and
terminal-type element. Users who draw the dots and bends where wires
branch as terminal-type symbols (114_connections) get one empty row per
junction: 109 of 151 rows on one reported cabinet.

Two options, both off by default so existing exports are unchanged:
- leave out the contact blocks: --no-slaves, "no_slaves" in qet_export,
  or uncheck the new "Contacts esclaves" element type in the dialog;
- leave out the junctions: terminal-type elements with no label,
  designation, manufacturer or manufacturer reference. --no-junctions,
  "no_junctions", or "Laisser de côté les jonctions" in the dialog.
  A terminal block with a label or a part number stays.

The element type filter had no box for slaves, so every query it built
left them out: the export dialog never listed contact blocks, although
the command line has since #849. The dialog now checks the new box by
default and gives the same rows as --export-bom. The box is unchecked by
default elsewhere, so nomenclature tables keep their rows.

docs/smart-device-bom.md still said slaves and terminals were excluded;
corrected.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 22:08:44 +13:00

99 lines
4.3 KiB
C++

/*
Copyright 2006-2025 The QElectroTech Team
This file is part of QElectroTech.
QElectroTech is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 2 of the License, or
(at your option) any later version.
QElectroTech is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with QElectroTech. If not, see <http://www.gnu.org/licenses/>.
*/
#ifndef CLI_EXPORT_H
#define CLI_EXPORT_H
#include <QStringList>
/**
@brief Headless command-line export.
Implements the long-requested batch/headless export
(qelectrotech.org bugtracker #171, GitHub #309): render a project's
diagrams to files without opening the GUI.
Detected and handled in main() before the GUI is created.
*/
namespace CLIExport {
/**
@brief True if @p args request a CLI export
(i.e. contain one of the export options).
*/
bool isExportRequest(const QStringList &args);
/**
@brief Run the CLI export described by @p args.
@return process exit code (0 on success).
Usage:
qelectrotech --export-pdf <project.qet> <output.pdf> [--show-terminals]
qelectrotech --export-png <project.qet> <output_dir> [--show-terminals]
qelectrotech --export-svg <project.qet> <output_dir> [--show-terminals]
qelectrotech --export-dxf <project.qet> <output_dir> [--show-terminals]
qelectrotech --export-cables <project.qet> <output.csv>
qelectrotech --export-wires <project.qet> <output.csv>
qelectrotech --export-bom <project.qet> <output.csv> [--no-slaves] [--no-junctions]
qelectrotech --export-wiring <project.qet> <output.csv>
qelectrotech --export-nets <project.qet> <output.json>
qelectrotech --export-links <project.qet> <output.csv>
qelectrotech --info <project.qet> [output.json]
qelectrotech --check-elements <element.elmt | directory>
qelectrotech --resave <project.qet> <output.qet>
qelectrotech --set-titleblock <project.qet> <output.qet> key=value...
PDF: one multi-page document (one diagram per page).
PNG/SVG/DXF: one file per diagram, named <output_dir>/<NN>_<title>.<ext>.
DXF: the same file the export dialog writes with its default options
(the export settings of the preferences).
--show-terminals: also paint terminal markers (red stroke + blue
docking dot) and terminal names, as the interactive editor
does; off by default, matching the GUI export dialog's
default. For DXF, draws the terminal markers. Has no effect on
the list export modes.
cables: wiring list (one row per conductor) as CSV.
wires: list of distinct wire numbers as CSV.
bom: bill of materials (one row per element) as CSV.
--no-slaves: leave the contact blocks (slave elements) out of the
bill of materials.
--no-junctions: leave the junctions out of the bill of materials:
terminal-type elements with no label, designation,
manufacturer or manufacturer reference.
wiring: from-to wiring list (one row per conductor) as CSV, read from
the project database. Same logical list as `cables`, which
reads the document XML instead; the two are meant to agree,
so diffing them checks that the database still describes the
project.
nets: electrical nets (connected-terminal groups) as JSON.
links: element cross-references (coil/contact) as CSV, with
unresolved links flagged.
info: structural project summary as JSON (stdout, or a file) —
per-page element / conductor counts and unconnected terminals.
check-elements: validate .elmt file(s) against the element schema.
resave: load and rewrite the project XML (round-trip integrity).
set-titleblock: stamp title-block fields onto every folio, then save.
Keys: title, author, date (or date=today), plant, location,
revision, version, filename; any other key becomes a custom
field. E.g. --set-titleblock in.qet out.qet revision=B date=today
*/
int run(const QStringList &args);
}
#endif // CLI_EXPORT_H